Furnaces
Condensing Furnaces
Tier Model Number Mounting Size Fan Speed / Stages Efficiency Notes:
Best YP9C M/P 60 - 120 MBH ECM Modulating 98% Quietest & Highest Eff Furnace Availible
Better TM9X M/P 60 - 120 MBH X-13 1-Stg. / 5-Speed 95.5% X-13 Motor for Higer AC Efficiency
Good TG9S M/P 40 - 130 MBH PSC 1-Stage 95.5% Const. Vol. (All modes) + Twinning Capable
Non Condensing Furnaces
Best YPLC M/P 60 - 120 MBH ECM Modulating 80% Mod Gas Valve + ECM Motor
Better TMLX M/P 60 - 120 MBH X-13 1-Stg / 5-Speed 80% X-13 Motor for Higer AC Efficiency
Good TGLS M/P 40 - 130 MBH PSC 1-Stage 80% Const. Vol. (All modes) + Twinning Capable
Special GY8S-E Up/Horiz Only 160 MBH Belt Drive Single Stage 80% Up to 3500 CFM / 7.5 Tons
Note: M/P refers to a furnace that may be configured for upflow, downflow or horizontal installations.
Note: Mixing Boxes from ProVent are avilible for all furnaces - availible with Economizer and CO2/Demand Controlled Ventiliation controls.
 
A/C Condensers
Tier Model Number Mounting Size Fan Speed / Stages Efficiency Notes:
Best CZH Top Disch. 2 - 5 tons 2-Stage 18
Better CZE Top Disch. 2 - 5 tons 2-Stage 15
Good YCJD-4 1-ph. Top Disch. 1.5 - 5 tons 1-Stage 13
YCJD-4 3-ph. Top Disch. 2.5 - 5 tons 1-Stage 13
Special YCHD 1-ph. Horiz. Disch. 1.5 - 5 tons 1-Stage 13 Horizontal Discharge
YCHD 3-ph. Horiz. Disch. 2.5 - 5 tons 1-Stage 13 Horizontal Discharge
 
HP Condensers
Tier Model Number Mounting Size Fan Speed / Stages Efficiency Notes:
Best YZH Top Disch. 2 - 5 tons 2-Stage 18
Better YZE Top Disch. 2 - 5 tons 2-Stage 15
Good YHJD-4 1-ph. Top Disch. 1.5 - 5 tons 1-Stage 13
YHJD-4 3-ph. Top Disch. 2.5 - 5 tons 1-Stage 13
 
Fan Coil - Air Handlers
Tier Model Number Mounting Size Fan Speed / Stages Efficiency Notes:
Best AVY M/P 2 - 5 tons ECM Modulating
Better AHX M/P 1.5 - 5 tons X-13 4 & 5 Speed
F6 FP Up/Horiz. Only 1.5 - 5 tons X-13 5-Speed
Good AHP M/P 1.5 - 5 tons PSC 4-Speed
F4 & F5 FP Up/Horiz. Only 2 - 5 tons PSC 3 & 4 Speed
Special MV Modular M/P 3 - 5 tons ECM Modualting
Note: Mixing Boxes from ProVent are avilible for all fan coils (air handlers) - availible with with Economizer and CO2/Demand Controlled Ventiliation controls.
Note: All fan coils (air handlers) availible with single and 3-phase electric heat kits.
 
Furnace Coils
Tier Model Number Mounting Size Fan Speed / Stages Efficiency Notes:
Best MC M/P 1.5 - 5 tons High Efficieny Up/Down/Horizontial
Better FC Up/Down 1.5 - 5 tons Upflow & Downflow only
HC Horizontal 1.5 - 5 tons High Efficiency Horizontal Coil
Good HD Horizontal 1.5 - 5 tons Narrow Horizontal coil
PC Up only 1.5 - 5 tons Partially Cased - Upflow Only
Special G2FD090 Up Only 5 - 7.5 ton Single Circuit 7.5-ton coil for Belt Drive (GY8S) Furnace
Vx-Hx Up Only or Horiz Only Dual Circuit Coils for Belt Drive & Twinned Furnaces
Note: Always verify the condenser + coil pairing via the listings in the condenser tech literature.
Note: Due to seasonal availibility issues, US Air will occassionally substitute York evap's with ADP evap's. Any substitutions will be higher Eff. & Cap. pairings.